Jump directly to content

Calibration of force measuring equipment at The National Laboratory

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Calibration of force measuring equipment at The National Laboratory Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

The national Laboratory of Force and Torque offers calibration of force transducers, load cells, measuring brackets, dynamometers and crash sensors.

Purpose/Benefit:

The national laboratories are responsible for maintaining the national reference standards for each measurement quantity and spreading metrological competence and traceability to industry and society at large. The national reference standards are the highest level of traceability in Sweden.

A calibration performed at a national laboratory fulfils all typical traceability and accreditation requirements that commonly exist in industry and society at large. 

Method (what/which methods are used to perform the service):

Normals 

Forces up to 100 kN are generated with "dead weight", which means allowing well-determined masses to be affected by the local gravitational field.

Forces from 100 kN to 1 MN are produced by mechanical exchange of deadweight force and forces up to 6 MN (pressure forces only) are generated by a hydraulic loading machine.

Standard calibration

For calibration of force transducers and dynamometers not having the same high accuracy requirements, we can use a type of load rig (material testing machine) with the associated reference sensor instead of our dead weight machine. However, the reference sensors are always traceable to our dead weight machine.

Measurement Uncertainty

Measurement area                                   Best measurement uncertainty (%)

1 N – 1 MN                                                     0,01

1 MN – 6 MN (pressure)                        0,05

We can also perform calibrations on site at our customers.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

The calibration results are reported in a digital calibration certificate in Swedish or English which states that the calibration was performed at a national laboratory. 

Area:
Calibration
Generic metrology and measurement technology
Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Calibration contact for force measuring equipment
Mikolaj Wozniak, TIC- ingenjör
Force and Torque
Field measurements: No Price type: 1 Division: Division Safety and Transport Preparation: No preparation required Link to order form: Website Calibration Certification and marking: Not applicable Type of service: Calibration Instrument: Power / torque sensors General area: Force and torque Order information: Order can be sent to risekalibrering@ri.se, or through the case management in our customer website Calibration. Divison (OLD): Division Safety and Transport Delivery level: National Metrology Institute
forcetorque@ri.se,mikolaj.wozniak@ri.se
/en/node/9710
Order
form
National Metrology Institute Sekundär områdes navigation:
Metrology
Production and manufacturing
Materials and durability
Tjänstetyp tagg: Kalibrering

Calibration of colour meters at The National Laboratory

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Calibration of colour meters at The National Laboratory Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

The National Laboratory for Photometry and Radiometry offers calibration of colour meters.

Purpose/Benefit:

The national laboratories are responsible for maintaining the national reference standards for each measurement quantity and  spreading metrological competens and traceability to industry and society at large. The national reference standards are the highest level of traceability in Sweden. 

A calibration performed at a national laboratory fullfils all typical traceability and accreditation requirements that commonly exist in industry and society at large.

Method (what/which methods are used to perform the service):

RISE are able to calibrate most types of colour meters. The calibration is performed using ceramic colour standards in various colours and shades of grey. The calibration is available for multiple measurement geometries e.g. 45°/0°, 8°/t och 8°/d. Other geometries can also be accommodated. We offer both 2° and 10° standard observers as well as standard illuminants A, C and D65. 

The calibrations takes place at the laboratory for photometry and radiometry in Borås.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

The calibration results are reported in a digital calibration certificate in Swedish or English which states that the calibration was performed at a national laboratory.

Area:
Calibration
Generic metrology and measurement technology
Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Contact calibration
Maria Nilsson Tengelin, Forskare
Colour standards
Field measurements: No Price type: 1 Division: Division Safety and Transport Preparation: No preparation required Link to order form: Website Calibration Certification and marking: Not applicable Type of service: Calibration Instrument: Not applicable General area: Photometry and radiometry Order information: Order can be sent to risekalibrering@ri.se, or through the case management in our customer website Calibration Divison (OLD): Division Safety and Transport Delivery level: National Metrology Institute
risekalibrering@ri.se
/en/node/9710
Request for quote
form
National Metrology Institute Sekundär områdes navigation:
Metrology
Sensors and sensor systems
Production and manufacturing
Tjänstetyp tagg: Kalibrering

The National Laboratory for Sound and Vibration

National Laboratory Sound and Vibration
Microphone

RISE is the National Metrology Institute of Sweden and is responsible, through its National Laboratories, for the fundamental measurement quantities in the International System of Units (SI).

At the National Laboratory for Sound and Vibration, we offer Sweden's most comprehensive and accurate resources for measurements and calibrations in the fields of sound and vibration. We continuously work to develop and improve measurement methods to meet the demand for traceable measurements from both industry and society, often in collaboration with other organizations through national and international research projects.

We work with quantities such as sound pressure, sound intensity, sound power, and acceleration. Both sound (dB) and vibration (m/s²) are derived quantities, which means that traceability is obtained from other quantities. For example, vibration is traceable to length and time.

What do we do?

  • Maintain traceability in sound and vibration
  • Quality-assured measurements and calibrations of sound level meters, sound calibrators, microphones, accelerometers, vibration transducers, tapping machines, and building acoustics loudspeakers etc.
  • Provide advice and technical expertise, such as in investigations of measurement needs or measurement quality in the field
  • Offer training in measurement and measurement uncertainty analysis
  • Conduct research and development, both nationally and in international research projects
  • Participate in international comparison measurements to maintain the highest measurement quality
  • Contribute to standardization

Håkan Andersson

FoU ingenjör
+46 10 516 54 23 Read more about Håkan
Profile image

Contact Håkan

CAPTCHA

* Mandatory 

By submitting the form, RISE will process your personal data.
Division (OLD): Division Safety and Transport Division: Division Safety and Transport National Metrology Institute Sekundär områdes navigation: Metrology

Calibration of spectroradiometers at The National Laboratory

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Calibration of spectroradiometers at The National Laboratory Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

The National Laboratory for Photometry and Radiometry offers calibration of spectroradiometers.

Purpose/Benefit:

The national laboratories are responsible for maintaining the national reference standards for each measurement quantity and  spreading metrological competens and traceability to industry and society at large. The national reference standards are the highest level of traceability in Sweden.

A calibration performed at a national laboratory fullfils all typical traceability and accreditation requirements that commonly exist in industry and society at large.

Method (what/which methods are used to perform the service):

The national laboratory can calibrate spectroradiometers in the range 200 nm to 2500 nm. 

The calibration involves using the software for the spectroradiometer to generate a calibration file. A spectral irradiance standard is used as a reference in the calibration. The range 200 nm to 250 nm is currently outside the scope of our traceability but this range can be added to the calibration by extrapolating from known values for a deuterium source. 

The calibrations takes place at the laboratory for photometry and radiometry in Borås.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

The calibration results are reported in a digital calibration certificate in Swedish or English which states that the calibration was performed at a national laboratory.

When becoming a client you will also get access to our customer website for calibration, where you may also place orders. 

Customer website for calibration

Area:
Calibration
Generic metrology and measurement technology
Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Contact calibration
Ingemar Svensson, Ingenjör
Spectroradiometer
Field measurements: No Price type: 1 Division: Division Safety and Transport Preparation: Description of preparation Preparation information:

Since the software for the spectroradiometer is required for a calibration it may happen that the customer needs to provide access to the software in cases where RISE does not have access to the software internally. 

Link to order form: Website Calibration Certification and marking: Not applicable Type of service: Calibration Instrument: Radiometers General area: Photometry and radiometry Order information: Order can be sent to risekalibrering@ri.se, or through the case management in our customer website Calibration Divison (OLD): Division Safety and Transport Delivery level: National Metrology Institute
risekalibrering@ri.se
/en/node/9710
Request for quote
form
National Metrology Institute Sekundär områdes navigation:
Metrology
Energy and electrification
Tjänstetyp tagg: Kalibrering

The National Laboratory for Electrical Quantities

The National Laboratory for Electrical Q
Resistance standards in oil bath

RISE is Sweden's NMI (National Metrology Institute) and is, according to the Swedish constitution, responsible for the fundamental measurement quantities in the International System of Units, SI.

The National Laboratory for electrical quantities is part of RISE’s Measurement Technology Department. We realise the electrical units that are important for Swedish industry. The realisation of each unit is based on definitions according to the SI system.

Electrical metrology also plays an important role for certain quantities that are not inherently electrical but are realised by electronic means. An example is the new kilogram which, since 20 May 2019, is no longer defined by the kilogram cylinder in Paris, but by Planck’s constant. At present RISE is building a Kibble balance which will be Sweden’s new, electronic, realisation of the kilogram.

In addition to the realisation of the SI-units that are used for each electrical quantity, we also carry out calibrations, measurements, evaluations, and conduct research within each area.   

Our electrical quantities (units) include:

Voltage (volt)
Resistance (ohm)
Current (ampere)
Capacitance (farad)
Inductance (henry)
Electric power (watt)

More information about each quantity can be found on our expertise and service pages. For high voltage, above 1000V, and high currents, above 100 A, we refer to our National Metrology Institute for high voltage and high currents. High frequencies, in the megahertz range and above, are referred to the National Metrology Institute for high frequencies and microwave electronics.

Ove Gunnarsson

TIC-ingenjör
+46 10 516 54 13 Read more about Ove

Contact Ove

CAPTCHA

* Mandatory 

By submitting the form, RISE will process your personal data.
Division (OLD): Division Safety and Transport Division: Division Safety and Transport National Metrology Institute Sekundär områdes navigation: Metrology

Calibration standards for form measurements at The National Laboratory

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Calibration standards for form measurements at The National Laboratory Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

The National Laboratory for Length and Dimensional Metrology offers calibration of form standards intended for use with form measuring devices.

Purpose/Benefit:

The national laboratories are responsible for maintaining the national reference standards for each measurement quantity and spreading metrological competence and traceability to industry and society at large. The national reference standards are the highest level of traceability in Sweden.

A calibration performed at a national laboratory fulfils all typical traceability and accreditation requirements that commonly exist in industry and society at large. 

Method (what/which methods are used to perform the service):

Form measurements includes parameters such as roundness, cylindricity, straightness and flatness. The definitions of these parameters will be found in ISO 1101. Roundness standards, reference cylinders, straightness standards and flatness standards are calibrated in accordance with these definitions. We offer also calibration of measuring instruments for form and amplification standards for roundness testers. The measuring methods that are used in the calibrations are based on tactile measurements.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

The calibration results are reported in a digital calibration certificate in Swedish or English which states that the calibration was performed at a national laboratory.

Area:
Calibration
Generic metrology and measurement technology
Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Marianne Äremann, Tekniskt ansvarig
Contact for the national laboratory for dimension
spherical standard
Field measurements: No Price type: 2|Tjänstens pris (om tillämpat, t.ex prispaket, prislistor) Priceinformation:

Price at request.

Division: Division Safety and Transport Preparation: No preparation required Link to order form: Website Calibration Standards:

ISO 1101

Certification and marking: Not applicable Type of service: Not applicable Instrument: Not applicable General area: Length and geometry Order information: Order can be sent to risekalibrering@ri.se, or through the case management in our customer website Calibration. Divison (OLD): Division Safety and Transport Delivery level: National Metrology Institute
mtd_kalibrering_105101@ri.se
/en/node/9710
Order
form
National Metrology Institute Sekundär områdes navigation:
Metrology
Construction
Production and manufacturing
Tjänstetyp tagg: Kalibrering

Calibration of line scales at The National Laboratory

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Calibration of line scales at The National Laboratory Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

The National Laboratory for Length and Dimensional Metrology offers calibration of line scales.

Purpose/Benefit:

The national laboratories are responsible for maintaining the national reference standards for each measurement quantity and spreading metrological competence and traceability to industry and society at large. The national reference standards are the highest level of traceability in Sweden.

A calibration performed at a national laboratory fulfils all typical traceability and accreditation requirements that commonly exist in industry and society at large. 

Method (what/which methods are used to perform the service):

We offer calibration of line scales, from very accurate microscope scales (stage micrometers, glass scales) of a few mm in length, to workshop scales (steel rulers) up to 3000 mm.

Line scales are calibrated in a measuring machine using a microscope for reading of the scale lines and a laser interferometer to measure the distances between the lines. The finest, most accurate scales, manufactured of metal or glass are calibrated using a machine vision system, to detect the scale lines.

For less accurate scales with coarser lines, we use a measuring machine with a manual reading microscope to detect the lines. This method is applied on line scales up to 3000 mm. The zero point on these scales can be defined as the first scale line or at the edge of the scale.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

The calibration results are reported in a digital calibration certificate in Swedish or English which states that the calibration was performed at a national laboratory.

Area:
Calibration
Generic metrology and measurement technology
Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Marianne Äremann, Tekniskt ansvarig
Contact for the national laboratory for dimension
Glass scale
Field measurements: No Price type: 2|Tjänstens pris (om tillämpat, t.ex prispaket, prislistor) Priceinformation:

Price at request.

Division: Division Safety and Transport Preparation: No preparation required Link to order form: Website Calibration Certification and marking: Not applicable Type of service: Not applicable Instrument: Not applicable General area: Length and geometry Order information: Order can be sent to risekalibrering@ri.se, or through the case management in our customer website Calibration. Divison (OLD): Division Safety and Transport Delivery level: National Metrology Institute
marianne.aremann@ri.se,mtd_kalibrering_105101@ri.se
/en/about-rise/operations/mission-governance/policy-documents/privacy-policy
Order
form
National Metrology Institute Sekundär områdes navigation:
Metrology
Production and manufacturing
Tjänstetyp tagg: Kalibrering

Calibration of measuring equipment on-site (National Laboratory)

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Calibration of measuring equipment on-site (National Laboratory) Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

The National Laboratory for Length and Dimensional Metrology offers calibration of measuring equipment on-site.

Purpose/Benefit:

The national laboratories are responsible for maintaining the national reference standards for each measurement quantity and spreading metrological competence and traceability to industry and society at large. The national reference standards are the highest level of traceability in Sweden.

A calibration performed at a national laboratory fulfils all typical traceability and accreditation requirements that commonly exist in industry and society at large. 

Method (what/which methods are used to perform the service):

Heavier equipment, such as measuring machines, generally must be calibrated where they stand. The National Laboratory for Length and Dimensional Metrology performs field calibrations of measuring equipment, where high accuracies are needed. We use physical standards as well as laser interferometers, depending on the properties of the measuring equipment that needs calibration. The temperature is carefully surveyed during the calibration process and when needed we make temperature corrections of the results.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

The calibration results are reported in a digital calibration certificate in Swedish or English which states that the calibration was performed at a national laboratory.

Area:
Calibration
Generic metrology and measurement technology
Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Agneta Jakobsson, Ställföreträdande teknikområdes ansvarig
Contact for the national laboratory for dimension
Measuring equipment
Field measurements: Yes Price type: 2|Tjänstens pris (om tillämpat, t.ex prispaket, prislistor) Priceinformation:

Price at request.

Division: Division Safety and Transport Preparation: No preparation required Link to order form: Website Calibration Certification and marking: Not applicable Type of service: Not applicable Instrument: Not applicable General area: Length and geometry Order information: Order can be sent to risekalibrering@ri.se, or through the case management in our customer website Calibration. Divison (OLD): Division Safety and Transport Delivery level: National Metrology Institute
mtd_kalibrering_105101@ri.se
/en/node/9710
Order
form
National Metrology Institute Sekundär områdes navigation:
Metrology
Production and manufacturing
Tjänstetyp tagg: Kalibrering

Calibration of step gauges at The National Laboratory

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Calibration of step gauges at The National Laboratory Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

The National Laboratory for Length and Dimensional Metrology offers calibration of step gauges.

Purpose/Benefit:

The national laboratories are responsible for maintaining the national reference standards for each measurement quantity and spreading metrological competence and traceability to industry and society at large. The national reference standards are the highest level of traceability in Sweden.

A calibration performed at a national laboratory fulfils all typical traceability and accreditation requirements that commonly exist in industry and society at large. 

Method (what/which methods are used to perform the service):

Step gauges up to 1500 mm are calibrated in a measuring machine fitted with special equipment for measuring these gauges. The measurement is made with a measuring probe on the measuring surfaces. A laser interferometer is used as a reference.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

The calibration results are reported in a digital calibration certificate in Swedish or English which states that the calibration was performed at a national laboratory.

When becoming a client you will also get access to our customer website for calibration, where you may also place orders. 

Customer website for calibration

Area:
Calibration
Generic metrology and measurement technology
Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Agneta Jakobsson, Ställföreträdande teknikområdes ansvarig
Contact for the national laboratory for dimension
Step gauge
Field measurements: No Price type: 2|Tjänstens pris (om tillämpat, t.ex prispaket, prislistor) Priceinformation:

Price at request.

Division: Division Safety and Transport Preparation: No preparation required Link to order form: Website Calibration Certification and marking: Not applicable Type of service: Calibration Instrument: Not applicable General area: Length and geometry Order information: Order can be sent to risekalibrering@ri.se, or through the case management in our customer website Calibration. Divison (OLD): Division Safety and Transport Delivery level: National Metrology Institute
mtd_kalibrering_105101@ri.se
/en/node/9710
Order
form
National Metrology Institute Sekundär områdes navigation:
Metrology
Production and manufacturing
Tjänstetyp tagg: Kalibrering

Measurement of surface texture and calibration of surface roughness standards

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Calibration of surface roughness standards at The National Laboratory Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

The National Laboratory for Length and Dimensional Metrology offers measurement of surface texture and calibration of surface roughness standards.

Purpose/Benefit:

The national laboratories are responsible for maintaining the national reference standards for each measurement quantity and spreading metrological competence and traceability to industry and society at large. The national reference standards are the highest level of traceability in Sweden.

A calibration performed at a national laboratory fulfils all typical traceability and accreditation requirements that commonly exist in industry and society at large. 

Method (what/which methods are used to perform the service):

Surface texture (roughness) is the microscopic structure, consisting of scratches, pores etc. that exists on a surface. It has great importance for industrially important properties such as friction, lubrication, corrosion, noise reduction and paint work.

Our services encompass both traceable calibrations of standards for surface roughness and evaluation of surface texture on manufactured components.

The extent of our services includes:

  • Calibration of roughness standards with regular or irregular profile
  • Calibration of step and depth standards
  • Calibration of instruments for the measurement of surface roughness
  • Characterization of surface texture on components

We are partners in the development of written standards for surface metrology and a member of the Swedish National Committee for Standardization (SiS) within the area.

 

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

The calibration results are reported in a digital calibration certificate in Swedish or English which states that the calibration was performed at a national laboratory.

Area:
Calibration
Corrosion
Generic metrology and measurement technology
Surface technology
Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Maria Haglund, TIC-ingenjör
Contact for the national laboratory for dimension
Surface roughness standards
Field measurements: No Price type: 2|Tjänstens pris (om tillämpat, t.ex prispaket, prislistor) Priceinformation:

Price on request.

Division: Division Safety and Transport Preparation: No preparation required Link to order form: Website Calibration Standards:

ISO 4287:1997

ISO 11562

Certification and marking: Not applicable Type of service: Calibration Instrument: Not applicable General area: Length and geometry Order information: Order can be sent to risekalibrering@ri.se, or through the case management in our customer website Calibration. Divison (OLD): Division Safety and Transport Delivery level: National Metrology Institute
mtd_kalibrering_105101@ri.se
/en/node/9710
Order
form
National Metrology Institute Sekundär områdes navigation:
Metrology
Production and manufacturing
Corrosion
Tjänstetyp tagg: Kalibrering