Testing of conservatories for certification by P-marking

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Testing of conservatories Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

Now there is the possibility for manufacturers to P-mark the conservatories. The P label means that the conservatories not only meets the legal and / or regulatory requirements but also other requirements that the market demands. P-marking means type-test, a quality and self-inspection which is monitored by an independent third party, in this case

Purpose/Benefit:

The purpose of the P-label is to give the consumers security when they buy the conservatories.

They are told clearly that there is security against personal injuries, that the conservatories have some water tightness and that the carrying capacity, the statute and the permanence correspond to high demands.

At the same time, the manufacturers get a good opportunity to demonstrate quality.

For consumers, the labeling means increased security.

Possibilities of having RISE wide expertise in several different areas, be able to verify the different properties of the conservatories such as water tightness, airtightness, safety against wind loads, durability or other qualitative properties through standardized tests.

Method (what/which methods are used to perform the service):

The certification rules CR 073 Uterum apply for P-marking of conservatories.

These offers:
testing of water tightness, airtightness and wind loads safety.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

The test is reported in a written report

Delivery time:

Submitted on request for quotation

Area: Construction Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Pontus Randén, Gruppchef
Thomas Henderson, Ingenjör
Conservatories
Field measurements: No Price type: 1 Division: Do not use - Division Built Environment Preparation: Description of preparation Preparation information:

Submitted on request for quotation

Standards:

Certification rules 073 Uterum

Certification and marking: Not applicable Type of service: Not applicable Instrument: Not applicable General area: Not applicable Order information: Please contact us for more information. Divison (OLD): Do not use - Division Built Environment Delivery level: Not applicable
pontus.randen@ri.se,thomas.henderson@ri.se
/en/about-rise/operations/mission-governance/policy-documents/privacy-policy
Application of interest
form
Construction Sekundär områdes navigation: Metrology Tjänstetyp tagg:
Certifiering
Provning

Testing of masonry units

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Testing of masonry units Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

Preparation and testing of masonry units as bricks and building blocks.

Purpose/Benefit:

Determination of dimensions, compressive strength, moisture movement, water absorption, frost resistance.

We help you with preliminary testing, type testing and ongoing self-inspection. The result can be part of quality assurance.

Method (what/which methods are used to perform the service):

For common methods, see under Standards or get in touch with the contact person.

We can perform both accredited and not accredited testing.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

Test report according method is included.

Delivery time:

Information about delivery time via the contact person.

Se allmänna villkor och särskilda villkor för ackrediterade uppdrag på Villkor | RISE.

Area:
Cement and concrete
Construction
Infrastructure
Built environment
Contact person (Enter one name per field. Activated personal contact pages will appear automatically): Thed Henriksson, TIC-ingenjör
brick
Field measurements: No Price type: 1 Division: Do not use - Division Built Environment Preparation: No preparation required Standards:

SS-EN 772-1 + A1 / 12390-3 Bestämning av tryckhållfasthet

SS-EN 772-13 Bestämning av netto och brutto torrdensitet (natursten undantaget)

SS-EN 772-14 Bestämning av fuktbetingade rörelser hos lättklinkerblock och fabrikstillverkad sten

SS-EN 772-16 Bestämning av mått

SS-EN 772-20/A1 Bestämning av planhet hos ytor

Frost resistance according to Annex A i EAD 170005-00-03-05. (Non-accredited)

Certification and marking: Not applicable Type of service: Testing / Analysis / Evaluation Instrument: Not applicable General area: Not applicable Order information: Order via contact person. Divison (OLD): Do not use - Division Built Environment Delivery level:
Accredited
Non-accredited
thed.henriksson@ri.se,
/en/node/9710
11. Sustainable cities and communities
Order
form
Construction Sekundär områdes navigation:
Metrology
Materials and durability
Tjänstetyp tagg: Provning

Concrete testing - Hardened concrete - Scaling at freezing

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Testing of frost resistance of concrete Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

Accredited testing of frost properties of concrete.

Purpose/Benefit:

Testing of frost properties of concrete. Order form is used.

Method (what/which methods are used to perform the service):

Testing of concrete in our frost laboratory in Borås, where we have more than 30 frost cabinets.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

Test report according to method is included.

See general and special terms and conditions applying to projects and accredited assignments Terms and conditions | RISE.

Delivery time:

Information about delivery time via the contact person.

Area:
Cement and concrete
Construction
Infrastructure
Built environment
Contact person (Enter one name per field. Activated personal contact pages will appear automatically): Fahrudin Mandal, Laboratorieingenjör
Frost resistance
Field measurements: No Price type: 1 Division: Do not use - Division Built Environment Preparation: No preparation required Standards:

SS 137244 Frostresistens, edition no 5

 

Certification and marking: Not applicable Type of service: Testing / Analysis / Evaluation Instrument: Not applicable General area: Not applicable Order information: Order via contact person or send the order form via e-mail. URL: https://www.ri.se/sites/default/files/2023-02/Order%20form%20hardened%20concret… Divison (OLD): Do not use - Division Built Environment Delivery level: Accredited
fahrudin.mandal@ri.se,
PDF for order form.: More information:

 Information about sample preparation at the laboratory

  • Cubes are sawn 21 ± 1 days after casting (drilled cores are sawn ≥ 20 days after casting).
  • Water saturation of samples will be done 7 days after sawing.
  • Start of freezing and thawing will start 10 days after sawing.

Sawing can only be done on Mondays, Tuesdays and Fridays.

It is important that samples arrive at the laboratory before the age of 19 days to assure correct preparation of samples.

National holidays might affect the testing procedure as preparation and testing can not be done on correct days. Please contact us for information if national holidays might affect the test procedure of your samples.

Deviations from the standard will be mentioned in the test report. 

Order
ordering
Concrete and cement Sekundär områdes navigation: Metrology Tjänstetyp tagg: Provning

Testing, inspection/audit and certification of aggregates for road, asphalt, mortar and concrete purposes

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Testing, audit inspection and certification of aggregates Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

Accredited tests for mechanical, physical, and chemical properties of aggregates and filler for road-, asphalt-, mortar- and concrete purposes according to EN 12620, EN 13043 and EN 13139. We also perform audit inspections in the above-mentioned areas with the Construction Products Regulation, CPR. RISE is a notified body in the area.

Purpose/Benefit:

Aggregates as above is included in system AVCP 2+ according to the Construction Product Regulation (CPR) which means type testing, auto control and external audit inspection for the manufacturer.

The results of the test and audit inspection consume, among other things, the basis for customers' CE marking against EN 12620, EN 13043 and EN 13139. This may be, for example, type testing or the manufacturer's auto control.

Tests that we perform are usually accredited, but we also perform tests according to methods that are not covered by our accreditation. At present, we can perform about 20 accredited methods in the ballast area.

We can also perform sample preparation and testing of rock samples or drill cores from new intended quarries.

See also our services in Petrographic analysis for aggregates, Alkali Silica Reactions – ASR, petrographic analysis, and Certification according to the Construction Products Regulation (CPR).

Method (what/which methods are used to perform the service):

Testing of aggregates and filler takes place in our laboratory located in Borås. Audit inspections take place at the manufacturer. See common methods under Standards.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

Test report and audit inspection report according to method/standard are obtained. The certification department has the ability to issue certificates.

See general and special terms and conditions applying to projects and accredited assignments Terms and conditions | RISE.

Delivery time:

For information about delivery time please contact us.

Area:
Cement and concrete
Construction
Infrastructure
Built environment
Contact person (Enter one name per field. Activated personal contact pages will appear automatically): Ida Lubera, Laboratorieingenjör
Aggregate sample dividing
Field measurements: No Price type: 1 Division: Do not use - Division Built Environment Preparation: No preparation required Standards:

SS-EN 933-1 Kornstorleksfördelning

SS-EN 933-3 Flisighetsindex (non-accredited)

SS-EN 933-4 LT-index (kornform) (non-accredited)

SS-EN 933-5 Andel krossade korn (non-accredited)

SS-EN 933-6 Flödestal (<4 mm) (non-accredited)

SS-EN 933-8 Finmaterialkvalitet, sandekvivalent (non-accredited)

SS-EN 933-10 Kornstorleksfördelning filler

SS-EN 1097-1 Motstånd mot nötning: micro-Deval

SS-EN 1097-2 Motstånd mot fragmentering: LA-tal

SS-EN 1097-6 Korndensitet och vattenabsorption

SS-EN 1097-7 Korndensitet filler

SS-EN 1097-8 Bestämning av poleringsvärdet (non-accredited)

SS-EN 1097-9 Motstånd mot nötning av dubbdäck: kulkvarn

SS-EN 1367-1 Frys-tö-provning i vatten

SS-EN 1367-6 Frys-tö-provning i saltlösning

SS-EN 1744-1 avsnitt 7 Vattenlöslig kloridhalt

SS-EN 1744-1 avsnitt 15.1 Organiska föroreningar: humus

SS-EN 1744-1 avsnitt 15.2 Organiska föroreningar: fulvosyra

SS-EN 196-2 del 4.4.2 Syralöslig sulfat, likvärdig provning med SS-EN 1744-1 avsnitt 12 (non-accredited)

SS 187186:2017 (fd SP0658) Total svavelhalt, likvärdig provning med SS-EN 1744-1 avsnitt 11:2

Certification and marking: Not applicable Type of service: Testing / Analysis / Evaluation Instrument: Not applicable General area: Not applicable Order information: Orders are placed through contact persons or send the order form via e-mail. Please send the completed order form together with the samples. Divison (OLD): Do not use - Division Built Environment Delivery level:
Accredited
Non-accredited
ida.lubera@ri.se,
PDF for order form.:
Order
ordering
Concrete and cement Sekundär områdes navigation:
Infrastructure
Metrology
Materials and durability
Tjänstetyp tagg:
Provning
Certifiering
Kontroll

Insulating glass units - Testing, injury investigations, education, certification, research and innovation.

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Testing of insulating glass units Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

RISE has extensive experience in the testing of insulating glass for P and CE marking. The test includes resistance to moisture ingress and measurement of gas content. We also carry out damage investigations on insulating windows of various kinds. Examples of properties that can be examined are gas content, contamination and condensation problems w

Purpose/Benefit:

RISE offers P-marking in the area of insulation glazing. Type tests are carried out according to Standard EN 1279-2.

RISE can also be helpful in the self-monitoring of the card IDs in accordance with EN 1279-6. RISE also performs damage investigations of various types on damages.

RISE has equipment for non-destructive measurement of insulating gas contents for both 2-glass and 3-glass constructions.

In addition to the possibility of P-marking insulating glass units, we also offer tests according to EN 1279-2, and -6.

With our long-standing experience in this field and access to a variety of cutting-edge expertise within the organization, we are a natural partner in investigations that are linked to various kinds of problems that may arise with insulating glass units, such as condensation problems, problems with gas filling concentrations, contaminations or emissions that can cause undesirable defects on insulating glass units, both directly on the surface of the glass as well as cavities between the glass.

 

Method (what/which methods are used to perform the service):

The following tests can be provided:

  • Testing for moisture penetration - Short-term testing according to EN 1279-6, Annex B4.
  • Testing for moisture penetration - Water vapor penetration according to SP method 254.
  • Testing gas concentration – The gas concentration according to SP method 3949.
  • Non-destructive testing of gas filling level in insulating glass of 2-glass and 3-glass constructions.

We also carry out investigations of various kinds on insulating glass units with errors.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

The test is reported in a written report

Delivery time:

Leave on request for quotation

Area: Construction Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Pontus Randén, Gruppchef
Thomas Henderson, Ingenjör
Insulating glass unit
Field measurements: No Price type: 1 Division: Do not use - Division Built Environment Preparation: No preparation required Preparation information:

Leave on request for quotation

Standards:

EN 1279-2

EN 1279-6, Annex B4.

SP-metod 254.

SP-metod 3949.

Certification and marking: Not applicable Type of service: Not applicable Instrument: Not applicable General area: Not applicable Order information: Please contact us for more information. Divison (OLD): Do not use - Division Built Environment Delivery level:
Accredited
Non-accredited
pontus.randen@ri.se,thomas.henderson@ri.se
/en/node/9710
Application of interest
form
Construction Sekundär områdes navigation: Metrology Tjänstetyp tagg: Provning

Chemical characterisation of the composition of an unknown sample or material

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Chemical analysis of material composition Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

We provide chemical analysis services to identify the composition and origin of unknown samples. In many cases, investigations can begin immediately, without the need for extensive planning or preparation.

Purpose/Benefit:

Our chemical analysis and troubleshooting services help answer a wide range of questions, such as:

  • What is the origin of a stain?
  • What is the composition of a deposit or residue?
  • What additives are present in a material or product?
  • How does the material change during aging?

Understanding, characterizing, and identifying the chemical composition of a sample is often essential for solving technical challenges or improving processes. Common issues we help investigate include:

  • Process‑related problems
  • Deposits and residues
  • Defects in products
  • Complaints and customer inquiries
  • Types and levels of additives
  • Comparison of products on the market
  • Presence of hazardous or regulated substances
  • Identification of plastic materials

Using a systematic and structured approach, we determine the material’s composition, identify substances, interpret the results, and pinpoint potential sources. The outcome includes both qualitative and quantitative information about the components present in the sample or material.

We employ a range of analytical techniques selected according to sample type and problem statement. Investigations can often start immediately, without the need for lengthy planning or preparation.

Method (what/which methods are used to perform the service):

We often use several different methods that combine organic analysis, inorganic analysis and microscopy analysis to characterize the unknown sample.

Examples of techniques:

  • Pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS)
  • Scanning electron microscope (SEM)
  • Scanning Electron Microscopy -Energy Dispersive Spectroscopy (SEM-EDS)
  • Inductively coupled plasma mass spectroscopy (ICP)
  • Ion chromatography (IC)
  • Gas chromatography/mass spectrometry (GC/MS)
  • Liquid chromatography–mass spectrometry (LC/MS)
  • Size Exclusion Chromatograph (SEC)
  • Fourier-transform infrared spectroscopy (FTIR)
  • Nuclear magnetic resonance (NMR)
  • Total organic carbon (TOC)
Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

Results are compiled in an analysis report.

Delivery time:

Normally within 1-2 weeks, quicker if urgent.

Area:
Bioeconomy
Biorefinery
Packaging
Chemical processes and products
Chemical and biological analysis
Corrosion
Pulp and paper
Plastics
Production and manufacturing
Product safety
Surface technology
Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Anders Reimann
Sofia Regnell Andersson, Forskare
chemical analysis
Field measurements: No Price type: 1 Division: Division Bioeconomy Preparation: No preparation required Certification and marking: Not applicable Type of service: Not applicable Instrument: Not applicable General area: Not applicable Order information: Please contact our experts through: problemsolving-analysis@ri.se Divison (OLD): Division Bioeconomy Delivery level: Not applicable
anders.reimann@ri.se,sofia.regnell.andersson@ri.se
/en/node/9710
More information:

Contact our experts through: problemsolving-analysis@ri.se



Order
form
Chemical and biological analysis Sekundär områdes navigation:
Metrology
Plastics
Production and manufacturing
Tjänstetyp tagg: Provning

Type testing of fire alarm products according to EN 54 and power supplies according to EN 12101-10

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Testing of Fire alarms Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

The Construction Products Regulation, CPR, requires certification of fire alarms and equipment used to ventilate fire gases from buildings. RISE can offer type testing documentation according to standards EN 54 and EN 12101-10 for these types of products.

Purpose/Benefit:

Fires are a major problem in society, costing lives and property annually. RISE has extensive equipment resources to counteract this, enabling us to offer effective type testing and thereby safe certification according to the CPR.

RISE's resources for testing and certification provide quality-assured market access and an opportunity to meet legal requirements for placing the product on the market.

Method (what/which methods are used to perform the service):

We conduct type testing in close collaboration with our experts in areas such as environmental tolerance testing, EMC, and software evaluation. With RISE's broad expertise and experience, we can handle many different types and combinations of testing assignments to meet the needs of your company.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

The test results are presented in one or more accredited test reports according to ISO/IEC 17025. The results are intended to form the basis for certification according to the Construction Products Regulation, CPR.

Area: Electronics Contact person (Enter one name per field. Activated personal contact pages will appear automatically): Örjan Johansson, Högskoleingenjör
Picture of a fire
Field measurements: No Price type: 1 Division: Division Safety and Transport Preparation: No preparation required Standards:

EN 54-2

EN 54-4

EN 54-11

EN 54-13

EN 54-17

EN 54-18

EN 54-21

EN 12101-10

ISO 21927-9

Certification and marking: Not applicable Type of service: Not applicable Instrument: Not applicable General area: Electricity Order information: Contact our contact person below Divison (OLD): Division Safety and Transport Delivery level: Accredited
orjan.johansson@ri.se,
/en/about-rise/operations/mission-governance/policy-documents/privacy-policy
Purpose - Header: Effective type testing for safe certification Metod - Header: Broad expertise and experience Delivery - Header: What happens after testing?
Request for quote
form
Fire safety Sekundär områdes navigation:
Metrology
Construction
Advanced electronics
Tjänstetyp tagg: Provning

Suspended ceilings.- Acoustic panels and baffles. Test methods according to EN13964:2014

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Testing of suspended ceilings Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

We provide testing of ceiling tiles according to the standard EN 13964: 2014.

We also offer rental of our test bed (Climate chamber) for own development testing (R&D).

Purpose/Benefit:

We provide documentation through tests for CE marking and DoP for acoustic tiles.

Obtaining results for essential properties as a basis for Dop & CE marking

Possibility of own R&D-like surveys with access to our climate chambers.

Method (what/which methods are used to perform the service):

The following tests can be offered:

Membrane components – Flexural tensile strength test (FTS) according to EN 13964:2014, Annex F

Mechanical strength, safety against failure – baffles, according to EN 13964:2014, Annex J

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

Report as a basis for CE marking and / or DoP.

Delivery time:

Leave on request for quotation

Area: Construction Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Pontus Randén, Gruppchef
Thomas Henderson, Ingenjör
Ceilings
Field measurements: No Price type: 1 Division: Do not use - Division Built Environment Preparation: Description of preparation Preparation information:

Leave on request for quotation

Standards:

EN 13964 Annex F and J

Certification and marking: Not applicable Type of service: Not applicable Instrument: Not applicable General area: Not applicable Order information: Inquiries are received via mail and telephone Divison (OLD): Do not use - Division Built Environment Delivery level: Not applicable
pontus.randen@ri.se,thomas.henderson@ri.se
/en/node/9710
Application of interest
form
Construction Sekundär områdes navigation:
Metrology
Production and manufacturing
Tjänstetyp tagg: Provning

External and internal doors - testing, damage investigation, educational courses, certification, research and innovation

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Testing of external and internal doors Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

External and internal doors are tested at RISE in a number of different ways. Testing is carried out to partly to investigate how new construction types work and partly as quality assurance with respect to the manufacturer’s product range. Here at RISE we investigate how external and internal doors perform when subjected to different climate variab

Purpose/Benefit:

Testing is carried out to partly to investigate how new construction types (and methods) work and partly as quality assurance with respect to the manufacturer’s product range.

Testing is conducted in a very thorough and careful manner, to see if and why any problems arise during the process.

The tests are carried out partly to examine how new designs work and also as quality control of manufacturers for their products.

Method (what/which methods are used to perform the service):

The following tests determinations can be offered (and the list is not exhaustive, we can consider all related testing in the doors scope):

  • Air permeability according to EN1026
  • Watertightness according to EN 1027
  • Resistance to wind load according to EN12211
  • Closing force according to EN12046-2
  • U-value according to EN-ISO 12567–1 or calculation according to EN 10077-2
  • Moisture and temperature stability according to EN 1121
Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

The customer receives a test report on completion of the investigation which shows how the door has compared with the class requirements laid down in the relevant classification standards connected to the testing standards mentioned above. 

The report includes explanations of the results achieved (often using photographs) by diagrams, tables and descriptions, plus a classification summary on the front page together with a short description of the test object. Drawings and detailed descriptions of the door supplied by the customer are included in the report appendix.

 

.  

Delivery time:

Delivery time will be given on request of a quote

Area: Construction Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Pontus Randén, Gruppchef
Richard Dawson, Teknologie magister
Doors
Field measurements: No Price type: 1 Division: Do not use - Division Built Environment Preparation: Description of preparation Preparation information:

Any required preparatory work will be advised on request of a quote

Standards:

Air permeability according to EN1026

Watertightness according to EN 1027

Resistance to wind load according to EN12211

Closing force according to EN12046-2

U-value according to EN-ISO 12567–1 or calculation according to EN 10077-2

Moisture and temperature stability according to EN 1121

Certification and marking: Not applicable Type of service: Not applicable Instrument: Not applicable General area: Not applicable Order information: Quote inquiries and order confirmations can be taken via E-mail or by telephone Divison (OLD): Do not use - Division Built Environment Delivery level: Accredited
pontus.randen@ri.se,richard.dawson@ri.se
/en/node/9710
Application of interest
form
Construction Sekundär områdes navigation:
Physical protection and safety
Metrology
Tjänstetyp tagg: Provning

Windows - testing, damage investigation, educational courses, certification, research and innovation

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Testing of windows Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

Windows are tested at RISE in a number of different ways. 

Here at RISE we investigate how windows perform when subjected to different climate variables in the form of rain, wind and cold. 

 

Purpose/Benefit:

Testing is carried out to partly to investigate how new construction types (and methods) work and partly as quality assurance with respect to the manufacturer’s product range. Testing is conducted in a very thorough and careful manner.

The tests are carried out partly to examine how new designs work and also as quality control of manufacturers for their products.

Method (what/which methods are used to perform the service):

The following tests determinations can be offered (and the list is not exhaustive, we can consider all related testing in the windows scope):

Air permeability according to EN1026

Watertightness according to EN 1027

Resistance to wind load according to EN12211

Operating forces according to EN12046-1

U-value according to EN-ISO 12567–1 or calculation according to EN 10077-2

Condensation test according to RISE methods 0736/5354

Moisture and temperature stability according to RISE method 258

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

The customer receives a test report on completion of the investigation which shows how the window has compared with the class requirements laid down in the relevant classification standards connected to the testing standards

The report includes explanations of the results achieved (often using photographs) by diagrams, tables and descriptions, plus a classification summary. Drawings and detailed descriptions of the window supplied by the customer are included in the report appendix.

Delivery time:

Delivery time will be given on request of a quote

Area: Construction Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Börje Gustavsson, Gruppchef
Richard Dawson, Teknologie magister
Window
Field measurements: No Price type: 1 Division: Do not use - Division Built Environment Preparation: Description of preparation Preparation information:

Any required preparatory work will be advised on request of a quote

Standards:

Air permeability according to EN1026

Watertightness according to EN 1027

Resistance to wind load according to EN12211

Operating forces according to EN12046-1

U-value according to EN-ISO 12567–1 or calculation according to EN 10077-2

Condensation test according to RISE methods 0736/5354

Moisture and temperature stability according to RISE method 258

Certification and marking: Not applicable Type of service: Not applicable Instrument: Not applicable General area: Not applicable Order information: Quote inquiries and order confirmations can be taken via E-mail or by telephone Divison (OLD): Do not use - Division Built Environment Delivery level:
Accredited
Non-accredited
borje.gustavsson@ri.se
/en/node/9710
Order
form
Wood technology Sekundär områdes navigation:
Physical protection and safety
Metrology
Tjänstetyp tagg: Provning