Jump directly to content

Testing of frost resistance of concrete

Accredited testing of frost properties of concrete.


This service is also relevant in: Metrology

Service details

Service
Concrete testing - Hardened concrete - Scaling at freezing
Delivery level
Accredited
Standards

SS 137244 Frostresistens, edition no 5

 

Price
Price on tender
Delivery time

Information about delivery time via the contact person.

Order

Order via contact person or send the order form via e-mail.

Fahrudin Mandal

Laboratorieingenjör
+46 10 516 68 58 Read more about Fahrudin

Contact Fahrudin

CAPTCHA

* Mandatory 

By submitting the form, RISE will process your personal data.

Purpose

Testing of frost properties of concrete. Order form is used.

Method

Testing of concrete in our frost laboratory in Borås, where we have more than 30 frost cabinets.

Deliveries

Test report according to method is included.

See general and special terms and conditions applying to projects and accredited assignments Terms and conditions | RISE.

More information

 Information about sample preparation at the laboratory

  • Cubes are sawn 21 ± 1 days after casting (drilled cores are sawn ≥ 20 days after casting).
  • Water saturation of samples will be done 7 days after sawing.
  • Start of freezing and thawing will start 10 days after sawing.

Sawing can only be done on Mondays, Tuesdays and Fridays.

It is important that samples arrive at the laboratory before the age of 19 days to assure correct preparation of samples.

National holidays might affect the testing procedure as preparation and testing can not be done on correct days. Please contact us for information if national holidays might affect the test procedure of your samples.

Deviations from the standard will be mentioned in the test report.