Thermal Conductivity Measurements According to ISO 22007:2
We measure thermal conductivity (i.e. heat conduction) using the Transient Plane Source (TPS) method according to ISO 22997-2 for which we are an accredited laboratory. The TPS method can be used to measure the thermal conductivity, diffusivity and the specific heat capacity on solids, liquids, gels and powder in temperatures between -50 °C and 600 °C.
We can also measure thermal conductivity using Transient Line Source (TLS) which is a fast and simple method with a limited temperature range between 0 °C and 100 °C.
Purpose/Benefit:Determination of thermal conductivity (λ) och diffusivity (α) and volumetric specific heat capacity (ρcp).
Method (what/which methods are used to perform the service):TPS
RISE is accredited for measurement of thermal conductivity according to ISO-22007-2, “Determination of thermal conductivity and thermal diffusivity - Part 2: Transient plane heat source (hot disc) method”. The method is specified for polymeric materials, but it is possible to measure on most solids and highly viscous materials as well as powders.
TLS
Transient Line Source method (TLS) according to ASTM D5334-14 is used for determination of thermal conductivity, which is simpler and faster than TPS when measuring. The temperature range for this measurement is between 0 °C and 100 °C.
Delivery (what does the client get after performed service – e.g. a report, certificate etc.):After the measurement has been performed, a report is delivered that describes the tests, conditions, the procedures and results.
Delivery time:The TPS measurements takes up to 1 week from the time the samples have arrived at RISE. Completed report is delivered within 3 weeks of the measurements being performed, a draft of the report can be delivered earlier.
The TLS measurements can often be made the day after the sample arrives at RISE. Completed report is delivered within 2 weeks of the measurements being performed.
Area: Testing Contact person (Enter one name per field. Activated personal contact pages will appear automatically):Hasan Sokoti, Forsknings- och utvecklingsingenjör
Johan Sjöström Field measurements: Yes Price type: 1 Division: Division Safety and Transport Preparation: Description of preparation Preparation information:
The samples must be prepared before taking any measurements. The samples must be manufactured or processed so that they meet the requirements that the sensors place on the sample geometry. We can also process the samples on RISE. We always condition the samples for 24 hours before the measurements are performed, unless otherwise requested.
Link to order form: hasan.sokoti@ri.se Standards:ISO 22007-2
Certification and marking: Not applicable Type of service: Testing / Analysis / Evaluation Instrument: Conductivity General area: Temperature Order information: Order via email Divison (OLD): Division Safety and Transport Delivery level:Accredited
Non-accredited
Construction
Materials and durability Tjänstetyp tagg: Provning