Jump directly to content

Fire test according to VOLVO STD 104-0001

VOLVO STD 104-0001, Flammability (burning behaviour) of interior and exterior materials


This service is also relevant in: Metrology, Automotive and future transport

Service details

Service
Fire test according to VOLVO STD 104-0001
Delivery level
Accredited
Standards

Similar test methods:

  • FMVSS 302
  • ISO 3795
Price
Price on tender
Preparations

Material consumption during test:

Complete test

  • Normally 5 part test. 8 specimen with dimension 100 mm x 356 mm.

Indicative test

  • 1 part test. 2 specimen with dimension 100 mm x 356 mm. 
Order

Before testing we ask you to complete the ”Order Specification form” and send this together with your order. Also attach product and safety data sheets when possible.


Order Specification Form

Henrik Fredriksson

Projektledare
+46 10 516 57 03 Read more about Henrik

Contact Henrik

CAPTCHA

* Mandatory 

By submitting the form, RISE will process your personal data.

Per Thureson

Senior Projektledare
+46 10 516 50 83 Read more about Per

Contact Per

CAPTCHA

* Mandatory 

By submitting the form, RISE will process your personal data.

Purpose

The method determines the burning rate of materials used internally in vehicles.

The main purpose of the test is to determine the burning rate of materials that are within 13 mm of the occupant compartment air space, in vehicles. Materials can be tested individually or in combination. The requirement is that the material must withstand a burning rate of 80 mm/min.

Method

The test is conducted inside a test chamber where the test specimen is mounted horizontally. The exposed side of the test specimen is subjected to a gas flame from underneath. The burnt distance and the time taken to burn this distance is measured during the test. The result, the burning rate, is expressed in mm/min.

Deliveries

A test report, in Swedish or English, is deliverd with the test results after testing.