Calibration of power quality instruments

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Calibration of power quality instruments Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

We offer calibrations for power quality parameters such as voltage, current and power for non-sinusoidal signals.

Purpose/Benefit:

Power quality is a summary concept for assessing the quality of delivered electricity. Voltage level, distortion and transients are some of the parameters that determine the quality. The instruments used to measure power quality are therefore multi-function instruments which are usually called power quality instruments.

Non-sinusoidal signals

Power quality deficiencies are often due to loads on the network, but can also be due to natural phenomena such as lightning strikes or incorrect connection actions by grid owners. The proportion of "bad" and "sensitive" loads has increased over the years, while the deregulation of the electricity market has meant that more parties are involved in the supply of electricity today, compared to before. Today, it is no longer possible to assume that all the voltages and currents of the electric power grid are almost sinusoidal. An increasing proportion of the motor loads are inverter controlled and the offices are filled with computers, IT equipment and so on. Virtually all lighting in offices and business premises and industries consist of fluorescent tubes or LED lamps. These loads do not draw sinusoidal current and therefore produce large harmonic currents which in turn give rise to harmonic voltages. Although conditions are far from ideal, measuring instruments are often calibrated for ideal sinusoidal voltages and currents. This is partly due to tradition, partly since it is significantly more difficult to measure with non-sinusoidal signals.

The need for measuring instruments that measure correctly even under these conditions has increased greatly, both ordinary instruments and power quality instruments. In many measuring contexts, for example in quality assurance, contracts or disputes, it is necessary to have calibrated measuring instruments. Reference instruments are needed that cannot only verify instruments under ideal conditions. At RISE, we can therefore offer calibration for voltage, current and power for non-sinusoidal signals.

By calibrating your instruments and measurement systems with us, you get high quality measurements and minimize losses due to measurement errors. Regular calibration will give you information about how stable the instrument measures.

Method (what/which methods are used to perform the service):

The basic function of a power quality instrument is to measure voltage, current, power and power factor. These functions are calibrated in the same way as a standard wattmeter. An extension of the basic function is to measure and save temporary peaks and dips in the voltage. The most common extra function of a power quality instrument is harmonic measurement, either to measure the level of individual harmonics or to measure the overall distortion level. Another common feature of these instruments is transient and flicker measurements.

With digital sampling technology as a basis, we have constructed a reference instrument, a digital sampling wattmeter, which, in addition to calibrating the above-mentioned quantities, can also be used for calibrating reactive and apparent power, power factor and total harmonic distortion.

Our reference instrument has, partly through our own verifications, partly through international comparison measurements, been found to have a measurement uncertainty that is within ±150 ppm in most situations. Through extensive research and development work, we can now offer calibration of even the most accurate instruments on the market.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

We issue calibration certificates in Swedish or English. On our customer website for calibration, you can directly download the calibration certificate and get all the other information you need about the measuring devices.

Area:
Energy
Calibration
Generic metrology and measurement technology
Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Stefan Svensson, Forskare
Glenn Bideberg, TIC-ingenjör
pm6680b
Field measurements: Yes Price type: 1 Division: Division Safety and Transport Preparation: No preparation required Link to order form: Calibration Certification and marking: Not applicable Type of service: Calibration Instrument:
Power meters
Electricity meters
General area: Electricity Order information: Order can be sent to risekalibrering@ri.se, or through the case management in our customer website Calibration. Divison (OLD): Division Safety and Transport Delivery level: National Metrology Institute
risekalibrering@ri.se
/en/node/9710
Order
form
Metrology Sekundär områdes navigation:
Energy transmission
Digital infrastructure
Tjänstetyp tagg: Kalibrering

Calibration of high voltage and high current equipment

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Calibration of high voltage and high current equipment Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

We perform all types of calibration services for high-voltage and high-current equipment, with the lowest possible measurement uncertainty. Services are performed in our high-voltage laboratory or on-site worldwide.

Purpose/Benefit:

We have the ability to generate and measure at megavolt levels and can work in several test paddocks simultaneously. All calibrations have full traceability to fundamental quantities. Calibrations are performed by a group with strong competence in the field, both world-renowned researchers and experienced engineers.

Method (what/which methods are used to perform the service):

The calibrations are carried out in our high voltage laboratory where we can generate the high voltages or currents required based on the customer's needs. We also offer a world-leading ability and competence to perform on-site calibration at customers worldwide. The methods we use meet the requirements of industry standards, such as IEC 60060–2 and IEC 61869-2.

Examples of calibration services:

  • Measuring system for alternating voltage (AC)
  • Measuring system for direct voltage (DC)
  • Measuring system for lightning- and switching impulse (LI/SI)
  • High voltage capacitors (capacitance and loss factor)
  • Capacitance bridges
  • High voltage AC power loss measurement system
  • Voltage and current transformers
  • Measuring system for direct current (DC) and alternating current (AC)
  • Current clamps and Rogowski coils
  • PD calibrators
  • µΩ meter
  • Ratio bridges
  • Insulation tester
  • Welding measuring equipment
  • Electronic loads 

Above is a selection of calibration services, please contact us to discuss your specific needs.
 

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

We issue calibration certificates in Swedish or English. On our customer website for calibration, you can directly download the calibration certificate and get all the other information you need about the measuring equipment.

Area:
Energy
Infrastructure
Calibration
Generic metrology and measurement technology
Built environment
Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Daniele Usai, Gruppchef
Contact calibration
Vishay divider
Field measurements: Yes Price type: 1 Division: Division Safety and Transport Preparation: No preparation required Link to order form: Website Calibration Standards:

IEC 60060, IEC 60270, IEC 60044 etc.

Certification and marking: Not applicable Type of service: Calibration Instrument:
Highvoltage probes / measuring systems
Capacitance
Conductivity
Bridges
Shunts (electrical)
General area: Electricity Order information: Order can be sent to risekalibrering@ri.se or highvoltage@ri.se, or through the case management in our customer website Calibration. Divison (OLD): Division Safety and Transport Delivery level: National Metrology Institute
risekalibrering@ri.se
/en/node/9710
Order
form
Metrology Sekundär områdes navigation:
Energy transmission
Sensors and sensor systems
Digital infrastructure
Tjänstetyp tagg: Kalibrering

Network architecture

Digital network architecture

Communication network services of today relies on multiple underlying technologies in order to facilitate efficient operations of a large variety of service requirements on e.g. bandwidth, latency, processing and memory.  We offer long standing knowledge in architectures and control, standardization of such converged infrastructures, and how to optimize and automate the control of these resources in a secure manner.

We bring our competence to the table and can assist you as partner in more long-term research projects or as short- to mid-term R&D consultants. By building our expertise in long-term research projects we can assist you in shorter term needs based on this expertise.

Our goal is to compliment you with R&D resources that support you with what is at the horizon of your roadmap, or what is already in your roadmap. Our experts range from multi-technology communication network and cloud experts, to optimization and automations experts, to software developers. This enables us to deliver higher TRL or more long-term proof-of-concepts implementations in line with your needs. We like to work closely to our partners in order to utilize our "big ears" efficiently. During agreed time periods we can sit with you and act in your teams, or we can support you in a more independent fashion where progress is discussed at continous meetings. We offer technical pre-studies, more in-depth studies, standardization support, software development support, and implementation of network functions.  

RISE wants to be your long term partner in R&D and communications networking where we independently and listening supports you in your challanges on both short and long term.

Anders Gavler

Projektledare
+46 70 652 49 38 Read more about Anders
Profile image

Contact Anders

CAPTCHA

* Mandatory 

By submitting the form, RISE will process your personal data.
Division (OLD): Division Digital Systems Division: Division Digital Systems Digital infrastructure

Calibration of luminance meter at The National Laboratory

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Calibration of luminance meter at The National Laboratory Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

The National Laboratory for Photometry and Radiometry offers calibration of any type of luminance meter or photometer.

Purpose/Benefit:

The national laboratories are responsible for maintaining the national reference standards for each measurement quantity and  spreading metrological competens and traceability to industry and society at large. The national reference standards are the highest level of traceability in Sweden. 

A calibration performed at a national laboratory fullfils all typical traceability and accreditation requirements that commonly exist in industry and society at large. 

Method (what/which methods are used to perform the service):

The calibration is performed according to existing international standards and recommendations. 

The calibration is performed against luminance source with CIE Standard Illuminant A (2856K) and can be performed at any luminance level from 0,01 cd/m2 to 500000 cd/m2. Instruments that measure luminance in foot-lamberts can also be calibrated. The standard service has a measurement uncertainty of 3% as a base but the measurement uncertainty can increase depending on the properties of the device under test as well as for luminance levels above 200000 cd/m2. If a lower measurement uncertainty is required then that can be discussed as a speciality service.  

The calibration takes place at the laboratory for photometry and radiometry in Borås.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

The calibration results are reported in a digital calibration certificate in Swedish or English which states that the calibration was performed at a national laboratory.

When becoming a client you will also get access to our customer website for calibration, where you may also place orders. 

Customer website for calibration

Area:
Calibration
Generic metrology and measurement technology
Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Contact calibration
Ingemar Svensson, Ingenjör
Luminance meter
Field measurements: No Price type: 1 Division: Division Safety and Transport Preparation: No preparation required Link to order form: Website Calibration Certification and marking: Not applicable Type of service: Calibration Instrument: Photometers General area: Photometry and radiometry Order information: Order can be sent to risekalibrering@ri.se, or through the case management in our customer website Calibration Divison (OLD): Division Safety and Transport Delivery level: National Metrology Institute
risekalibrering@ri.se
/en/node/9710
Request for quote
form
National Metrology Institute Sekundär områdes navigation:
Metrology
Sensors and sensor systems
Digital infrastructure
Tjänstetyp tagg: Kalibrering

Calibration of time and frequency via GNSS at The National Laboratory

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Calibration of time and frequency via GNSS at The National Laboratory Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

The National Laboratory for time and frequency offers calibration of time and frequence via GNSS.

Purpose/Benefit:

The National Laboratories have the task to maintain the national references standards for each measurement quantity and to spread metrological competens and traceability to industry and society at large. The national reference standards are the highest level of traceability in Sweden.

A calibration performed at a National Laboratory fullfils all typical traceability and accreditation requirements that commonly exist in industry and society at large. 

Method (what/which methods are used to perform the service):

For calibration of more accurate time and frequency standards, we offer on-site calibration using global navigation satellite systems, GNSS (e.g. GPS and Galileo) as an intermediate reference. This requires installation of equipment for reception and storage of data from the GNSS.

The method, known as GNSS Common View, is similar to that used by RISE to provide international traceability.

We can also verify and calibrate the time synchronising and positioning performance of different types of GNSS receivers. 

The method involves calibrating a frequency standard, clock or time scale (DUT) relative to UTC(SP) by means of simultaneous measurements of GPS satellite signals performed by both the customer and by RISE.  The use of common satellites eliminates many of the common measurement errors.  In addition, the changes that are observed in the time intervals [UTC(SP) – DUT] provide an estimate of the DUT frequency relative to UTC(SP).

All instrumentation needed (GNSS receiver, time interval counter, software, etc.) can be supplied and installed by RISE. For continuous monitoring over a longer period of time, equipment can be rented from RISE.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

For continuous monitoring, the measured values registered by the customer are transferred automatically to RISE.  The calculation of the results are performed automatically by RISE with the results being sent to the customer by (for example) e-mail.  The results can also be provided through a webpage. How often this is done is agreed with the customer, but can in principle be done on a daily basis.  The accuracy of frequency measurement, averaged over a day, is better than ±1E-13, but does depend on the quality of the DUT.

Area:
Calibration
Generic metrology and measurement technology
Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Contact calibration
Gustav Jönsson, Forskare
Field measurements: Yes Price type: 1 Division: Division Safety and Transport Preparation: Description of preparation Preparation information:

Installation of instrumentation at the customer is needed.

Link to order form: Website Calibration Certification and marking: Not applicable Type of service: Calibration Instrument: Not applicable General area: Time and frequency Order information: Order can be sent to risekalibrering@ri.se, or through the case management in our customer website Calibration Divison (OLD): Division Safety and Transport Delivery level: National Metrology Institute
risekalibrering@ri.se,gustav.jonsson@ri.se
/en/node/9710
Order
form
National Metrology Institute Sekundär områdes navigation:
Metrology
Digital infrastructure
Tjänstetyp tagg: Kalibrering

Calibration of stopwatches at The National Laboratory

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Calibration of stopwatches at The National Laboratory Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

The National Laboratory for time and frequency offers calibration of any type of stopwatches.

Purpose/Benefit:

The National Laboratories have the task to maintain the national references standards for each measurement quantity and to spread metrological competens and traceability to industry and society at large. The national reference standards are the highest level of traceability in Sweden.

A calibration performed at a National Laboratory fullfils all typical traceability and accreditation requirements that commonly exist in industry and society at large.

Method (what/which methods are used to perform the service):

The calibration is performed according to international standards and recommendations.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

The calibration results are reported in a digital calibration certificate in Swedish or English which states that the calibration was performed at a National Laboratory.

Area:
Calibration
Generic metrology and measurement technology
Contact person (Enter one name per field. Activated personal contact pages will appear automatically): Contact calibration
Stop watch
Field measurements: No Price type: 1 Division: Division Safety and Transport Preparation: No preparation required Link to order form: Website Calibration Certification and marking: Not applicable Type of service: Calibration Instrument: Stopwatches General area: Time and frequency Order information: Order can be sent to risekalibrering@ri.se, or through the case management in our customer website Calibration Divison (OLD): Division Safety and Transport Delivery level: National Metrology Institute
risekalibrering@ri.se
/en/node/9710
Order
form
National Metrology Institute Sekundär områdes navigation:
Metrology
Digital infrastructure
Total defence and crisis preparedness
Tjänstetyp tagg: Kalibrering

Testing of monopole antennas in the frequency range 9 kHz-30 MHz.

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Testing - Monopole antennas Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

Testing of monopole antennas for determining their antenna factor in the frequency range 9 kHz-30 MHz.

Purpose/Benefit:

To provide the antenna factor for monopole antennas in the frequency range 9 kHz-30 MHz.

Method (what/which methods are used to perform the service):

The antennas are tested according to the internal method 3556 in which the antenna rod is replaced by an equivivalent impedance.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

Report containing the antenna factors

Area: Electronics Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Mats Cedheim, Ingenjör
Fredrik Harrysson, Enhetschef
Field measurements: No Price type: 1 Division: Division Safety and Transport Preparation: No preparation required Certification and marking: Not applicable Type of service: Testing / Analysis / Evaluation Instrument: Antennas General area: Electricity Order information: E-mail or call the contact persons Divison (OLD): Division Safety and Transport Delivery level: Not applicable
mats.cedheim@ri.se
/en/node/9710
Order
form
Sensors and sensor systems Sekundär områdes navigation:
Metrology
Digital infrastructure
Tjänstetyp tagg: Provning

Accredited antenna calibration according to ANSI C63.5 (2017) in the frequency range 30 MHz-18 GHz

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Calibration - antennas Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

Accredited calibration of antennas according to standard ANSI C63.5 (2017) in the frequency range 30 MHz-18 GHz.

Purpose/Benefit:

To provide accredited antenna calibration in the frequency range 30 MHz-18 GHz for a multitude of different antenna types such as for example biconical antennas, horn antennas, dipole antennas, logperiodical antennas and hybrid antennas.

Accredited antenna calibration according to ANSI C63.5 is a requirement for antennas used in ANSI C63.4 testing.

Method (what/which methods are used to perform the service):

The calibration of the antennas takes place on one or both of our calibration ranges. For antenna calibration in the frequency range 30 MHz-1 Ghz the calibration is done on our OATS "Maxwell" according to the internal method 4429. If the antenna is to be calibrated in the frequency range 1-18 Ghz the calibration is performed in our fully anechoic chamber "Hertz" according to the internal method 5594. Both internal methods are 3-antenna calibration techniques according to the SSM in ANSI C63.5 (2017).

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

Calibration certificate containing the antenna gain and antenna factor, control of the reflection coefficient of the antenna.

Area: Electronics Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Mats Cedheim, Ingenjör
Fredrik Harrysson, Enhetschef
Field measurements: No Price type: 1 Division: Division Safety and Transport Preparation: No preparation required Standards:

ANSI C63.5 (2017)

Certification and marking: Not applicable Type of service: Calibration Instrument: Antennas General area: Electricity Order information: E-mail or call the contact persons Divison (OLD): Division Safety and Transport Delivery level: Accredited
mats.cedheim@ri.se
/en/node/9710
Application of interest
form
Metrology Sekundär områdes navigation:
Sensors and sensor systems
EMC
Digital infrastructure
Tjänstetyp tagg: Kalibrering

Testing of magnetic field meters/field probes in the frequency range 5 Hz-1 MHz

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Testing of magnetic field meters Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

Testing of magnetic field meters/field probes in the frequency range 5 Hz-1 MHz with field strength up to 10 uT

Purpose/Benefit:

To provide testing of magnetic field meters/field probes in the frequency range 5 Hz-1 MHz for field strength up to 10 uT 

The correction factor is used to improve the accuracy of the tested equipment.

Method (what/which methods are used to perform the service):

We test the equipment according to our internal metod 5031. This is done by placing the magnetic field meter/field probe in a calcuable known field created with a Helmholtz coil. The quota between the calculated applied field and the readout from the equipment gives a correction factor unique´for the specific equipment at the given frequency. 

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

Report containing the correction factors at requested frequencies

Area: Electronics Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Mats Cedheim, Ingenjör
Fredrik Harrysson, Enhetschef
Field measurements: No Price type: 1 Division: Division Safety and Transport Preparation: No preparation required Certification and marking: Not applicable Type of service: Testing / Analysis / Evaluation Instrument: Field meters and probes General area: Electricity Order information: E-mail or call the contact persons Divison (OLD): Division Safety and Transport Delivery level: Not applicable
mats.cedheim@ri.se
/en/node/9710
Order
form
Metrology Sekundär områdes navigation:
Sensors and sensor systems
Digital infrastructure
Tjänstetyp tagg: Provning

Calibration of electrical field probes/field indicators/field strength meters in the frequency range 10 kHz-18 GHz

Name of service (page headline, shown in promos – maximum of 70 characters incl. spaces): Calibration - Field measurement equipment Lead (include SEO-words and the main benefits for your target groups. Stick to one paragraph, maximum 2-3 sentences):

Tracible calibration of electrical field probes/field indicators/ field strength meters in the frequency range 10 kHz-18 GHz

Purpose/Benefit:

To provide tracible calibration of electrical field probes/field indicators/field strength meters in the frequency range 10 kHz-18 GHz.

The calibration will provide a correction factor which can be used to improve the accuracy in the calibrated equipment.

Method (what/which methods are used to perform the service):

The calibration of electrical field probes/field indicators/field strength meters takes place on one or both of our measurement ranges. For equipment used in the frequency range 10 kHz-50 MHz the calibration is conducted in our TEM cell. If the equipment is to be calibrated in the frequency range 50 MHz-18 GHz this takes place in our fully anechoic chamber "Hertz". The calibration is done according to internal methods, which are based on IEEE 1309-2013. All the calibrations are conducted by placing the equipment in a calculable electrical field and then recording the response of the equipment. The quota between the by the equipment displayed level and the applied field gives a correction factor that is unique for the specific equipment.

Delivery (what does the client get after performed service – e.g. a report, certificate etc.):

Calibration certificate containing the correction factors for the requested frequencies. The certificate is tracible to a NMI. 

Area: Electronics Contact person (Enter one name per field. Activated personal contact pages will appear automatically):
Mats Cedheim, Ingenjör
Fredrik Harrysson, Enhetschef
Calibration of field stregth meter
Field measurements: No Price type: 1 Division: Division Safety and Transport Preparation: No preparation required Certification and marking: Not applicable Type of service: Calibration Instrument: Field meters and probes General area: Electricity Order information: E-mail or call the contact persons Divison (OLD): Division Safety and Transport Delivery level: Accredited