ISO 5660-1 Fire testing of products in trains

ISO 5660-1 – Reaction-to-fire tests - Heat release, smoke production and mass loss rate

Part 1: Heat release rate (Cone calorimeter method) and smoke production rate (dynamic measurement)


This service is also relevant in: Metrology

Service details

Service
ISO 5660-1 Fire testing of products in trains
Delivery level
Accredited
Standards

Related standards: ISO 5658-2,       EN ISO 5659-2

Price
Price on tender
Preparations

Material needed for testing

Complete test

  • 6 specimens with dimensions 100 mm x 100 mm x nominal thickness (max 50 mm)

Indicative test

  • 2 specimens with dimensions 100 mm x 100 mm x nominal thickness (max 50 mm)
Order

Before testing we ask you to complete the ”Order Specification form” and send this together with your order. Also attach product and safety data sheets when possible to below contact person.

Anna Bergstrand

Affärsutvecklare
+46 10 516 58 54 Read more about Anna

Contact Anna

CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.

* Mandatory 

By submitting the form, RISE will process your personal data.

Susanne Blomqvist

Projektledare
+46 10 516 50 84 Read more about Susanne

Contact Susanne

CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.

* Mandatory 

By submitting the form, RISE will process your personal data.

Purpose

Fire testing according to ISO 5660-1 evaluates a number of different parameters such as heat release rate, smoke production rate, ignition properties, etc. The method is used to classify materials for trains and is referred to by EN 45545-2 - Railway applications - Requirements for fire behaviour of materials and Components.

When we take the railway, we assume that the journey will be comfortable and safe. Fire safety is important in order to save lives in the event of an accident. Therefore, all materials and products installed in trains and subways must be fire tested according to EN 45545-2. The system has been developed by Technical Committee CEN/TC 256 ”Railway applications” at the request of the European Commission. The system is based on requirements from EU Directive 2016/797.  All contradictory national standards are revoked.

Method

When testing a product according to ISO 5660-1, a sample with the dimension 100 mm x 100 mm is subjected to an irradiance level of either 25 kW/mor 50 kW/m2. The surface of the sample is heated and starts to emit pyrolysis gases that ignite by an electric spark igniter. The emitted gases are collected in a hood and transported away through a ventilation system. The heat release is measured using the data on measured oxygen concentration in the emitted smoke.

The following parameters are either measured: Time to ignition, heat release rate (kW/m2), ARHE (Average Rate of Heat Emission (kW/m2) and MARHE (Maximum Rate of Heat Emission) (kW/m2).

Deliveries

A test report, in Swedish or English, is delivered with the test results after testing.