Jump directly to content

Fire test according to UL 94 HB

UL94 HB - Horizontal Burning Test


This service is also relevant in: Metrology, Plastics

Service details

Service
Fire test according to UL94 HB
Delivery level
Accredited
Standards

Similar to UL94 HBF, HF-1 or HF-2.

Price
Price on tender
Preparations

Material consumption during testing.

• Complete testing 6 specimens with dimension 125 mm x 13 mm. Max thickness 13 mm.
• Indicativ test 2 specimens with dimension 125 mm x 13 mm. Max thickness 13 mm.

Order

Before testing we ask you to fill in the "Order specification form" and attach it with your order.


Order Specification form

Per Thureson

Senior Projektledare
+46 10 516 50 83 Read more about Per

Contact Per

CAPTCHA

* Mandatory 

By submitting the form, RISE will process your personal data.

Henrik Fredriksson

Projektledare
+46 10 516 57 03 Read more about Henrik

Contact Henrik

CAPTCHA

* Mandatory 

By submitting the form, RISE will process your personal data.

Purpose

The method is intended to be used as a preliminary indication of the fire behavior of products with regard to flammability in a particular application.

 The method measures the burn rate of a product horizontally. Examples of products that can be tested in this method: plastic, rubber, and other non-metallic materials.

Method

The test takes place in a test chamber where the specimen is mounted horizontally. A bunsen burner is applied at a 45° angle to the specimen for 30 seconds or until the flame front reach 25 mm. The time the material burns is registerd, also how long it takes for the flames to progress in the material. The result (Burning speed) is expressed in mm/min.

Deliveries

A test report, in Swedish or English, is deliverd with the test results after testing.