Jump directly to content

Fire test according to UL 94, V0, V1 and V2

Test for flammability of plastic materials for parts in devices and appliances<


This service is also relevant in: Metrology, Plastics

Service details

Service
Fire test according to UL 94, V0, V1 and V2
Delivery level
Accredited
Standards

Similar to test method UL94 5VA or 5VB, UL94 VTM-0, -1 or -2

Price
Price on tender
Preparations

Material consumption during testing

  • Complete testing 20 specimen with dimension 125 mm x 13 mm. Max thickness 13 mm.
  • One indicativtest 4 specimen with dimension 125 mm x 13 mm. Max thickness 13 mm.
Order

Please fill in the attached order specification form and attach it to your order


Order Specification form

Cecilia Lövström

TIC-ingenjör
+46 10 516 58 88 Read more about Cecilia

Contact Cecilia

CAPTCHA

* Mandatory 

By submitting the form, RISE will process your personal data.

Per Thureson

Senior Projektledare
+46 10 516 50 83 Read more about Per

Contact Per

CAPTCHA

* Mandatory 

By submitting the form, RISE will process your personal data.

Purpose

The method measures a product's flammability when exposed to a small flame.

The method is intended to be used as a preliminary indication of the fire behavior of products with regard to flammability in a particular application.

Method

The test takes place in a test chamber where the specimen is mounted vertically. Small amounts of cotton are placed under the specimen. A gas flame is applied for 10 seconds. The afterburning time in the material is noted. As soon as the flames in the material dies out, the gas flame is applied once more for 10 seconds. The test is conducted on materials conditioned for 48 hours in standard climates and on materials conditioned 168 hours at 70 °C. Five specimen from each conditioning set are to tested. The following test results are reported:

• Afterflame time for each individual tspecimen.
• Total afterflame time for each conditioning set.
• Afterflame time plus afterglow time for each individual specimen after second flame application.
• If the material burns or glows up to the mounting of the specimen.
• If the cotton is ignited by burning drops.

Deliveries

After testing, a test report is delivered in English or Swedish.