Large-scale product testing in extreme climates

In our large climate chambers, we can expose products to a variety of climates. This is to verify function and service life.


This service is also relevant in: Climate adaptation, Production and manufacturing, Materials and durability

Service details

Service
Climate simulation in a large climate chamber. Environmental durabilit
Instrument
Electricity meters, Flow meters, Air flow / Gas flow, Humidity sensor, Thermometers
Certifications
Other Certifications
Delivery level
Accredited
Field measurements
Available
Price
Price on tender
Preparations

Information about necessary preparations is sent out before the test


Order

CAPTCHA
By submitting the form, RISE will process your personal data.

Anna Kankkonen

Projektledare
+46 10 251 39 77 Read more about Anna

Contact Anna

CAPTCHA

* Mandatory 

By submitting the form, RISE will process your personal data.

Maria Sjöström

Enhetschef
+46 73 079 42 32 Read more about Maria

Contact Maria

CAPTCHA

* Mandatory 

By submitting the form, RISE will process your personal data.

Purpose

Climate simulation with extreme climates accelerates development and ensures function to quickly reach the market. At RISE, we have extensive experience of just such tests and can be your support throughout the project. Tests we normally perform in our climatic chambers is:

  • High Temperature
  • Low Temperature
  • Solar Radiation / Solar simulation
  • Humidity
  • Immersion
  • Icing/Freezing Rain

Method

Examples of test methods that can be performed:

IEC

MIL 810

Stanag

Deliveries

Results and analysis are delivered in a report if the customer wishes.

More information

Technical data: Climate chamber

Length: 20.6 m
Width: 6.0 m
Height: 5.5 m
Door: 3.75 x 5.0 m (width x height)

Technical data: Solar simulator

Floor area: 10 × 15 m
Illuminated area: 2.5 × 5.5 m
Ceiling height: About 7.0 m
Entrance: 4.0 × 4.0 m

Capacity:

Irradiance: 500 - 1200 W/m²
Temperature: -50 ° C to +95 ° C
Relative humidity: Between +20 ° C to +50 ° C / 20% RH to 95% RH
Temperature change: 0.5 ° C to 1.0 ° C / min