Jump directly to content

Inspection of garages and car parks

For several decades, RISE concrete assessors have inspected garages and car parks because they usually receive concrete damages. Most often, the damages are caused by chlorides from thawing salt, which is taken in with the cars during winter time. The chlorides penetrate the concrete and eventually cause the reinforcement to rust.


This service is also relevant in: Infrastructure, Built environment, Corrosion

Service details

Service
Survey of garages, car parks and parking decks
Instrument
Electrometers, Calipers
Field measurements
Available
Price
Price on tender

Application of interest

CAPTCHA
By submitting the form, RISE will process your personal data.

Per Martinell

Utredare
+46 10 516 68 29 Read more about Per

Contact Per

CAPTCHA

* Mandatory 

By submitting the form, RISE will process your personal data.

Gürsel Hakan Taylan

Forsknings- och utvecklingsingenjör
+46 10 516 68 77 Read more about Gürsel Hakan

Contact Gürsel Hakan

CAPTCHA

* Mandatory 

By submitting the form, RISE will process your personal data.

Causes of concrete damages

Initially, the reinforcement in the concrete is well protected against corrosion by the surrounding concrete's high pH value. Corrosion protection is broken if the chloride ion content, Cl-, in the concrete exceeds the concrete's so-called chloride threshold value.

The corrosion protection in the concrete can also be broken by carbonation. Carbonation is caused by carbon dioxide from the air penetrating the concrete and forming calcium carbonate, which lowers the pH value of the concrete, with the result that the concrete loses its original anti-corrosion properties.

When the reinforcement corrodes, so-called rust blasting occurs because the corrosion products (= rust) have a much larger volume than the original steel and the concrete layer over the reinforcement thus cracks and gradually splits loose.

In unheated garages and car parks, frost damage can also occur in the concrete.

Method

RISE's surveys of garages and car parks usually consist of visual inspection, damage mapping, measurements of covering concrete layers and carbonation depth, as well as chloride sampling.

Delivery

RISE inspections are usually compiled in verified reports, which usually include condition assessments and proposed measures.