Contact person
Hasan Sokoti
Forsknings- och utvecklingsingenjör
Contact HasanDifferent fluids and pastes have different thermal conductivities at different temperatures. We perform thermal conductivity measurement on different fluids as well as oils, coolants, colloidal suspensions, aerogels, etc
To determine the thermal conductivity (λ) on different fluids such as oils and pastes.
Transient Hot-Wire (THW) method according to ASTM D7896-19 for the determination of thermal conductivity, resistivity and diffusivity on different fluids and pastes. The measurements are performed in a temperature range between -50 and 100 °C.
After the measurements have been performed, a report is delivered that describes the test, the procedure, and results.
Thermal Conductivity Measurement on fluids and pastes using THW-method
Temperature
Energy, Calibration, Chemical processes and products, Pharmaceuticals, Material transition, Testing, Built environment, Water
Non-accredited
Available
ASTM D7896-19
Price on tender
1-2 weeks after that the material arrived at RISE
The materials need at least 24 hours conditioning before the measurements. It will be done by RISE.