Fire test according to SS 8760010 Health care textiles, Nursing beds

SS 8760010:2016 - Healthcare textiles – Nursing beds – Burning requirements for mattresses to be used in high risk Environment (NT FIRE 055)

Purpose

This method evaluates the burning behavior of mattresses intended for special purposes. The standard states the demands for basic fire requirements (flammability, smoke and heat output) of mattresses intended for care of patients who may ignite the mattress on purpose (e.g. mentally ill patients, jail interns etc ).
 

From a patient safety, and working environment point of view, it is necessary to set fire resistance requirements for nursing beds.

During a fire in a hospital ward the mattress is one of the components that constitute the greatest fire hazard because it can develop large amounts of heat and smoke.

Method

The test is performed in accordance with NT FIRE 055. The mattress is placed on a bed frame in metal. The test assembly is placed under a hood (calorimeter) that collects all the smoke produced during the test. The ignition source, which delivers 30 kW heat output, is applied in the middle and on top of the mattress for 120 s. A possible fire in the mattress should have self-extinguished no later than 3 minutes after the burner has been removed.
To simulate arson the mattress is prepared by two incisions in the centre of the mattress cover (perpendicular to each other), so that the mattress core (foam) is directly affected by the flames from the burner.

Deliveries

After testing, a test report in Swedish or English is delivered with the results.

Order

Before testing, we ask you to fill out the "Order Specification Form" and attach your order as well as any product and safety data sheets.

Order Specification Form

Service

Fire test according to SS 8760010 Health care textiles, Nursing beds

Delivery level

Accredited

Standards

  • Related standard: NT Fire 055

Price

Price on tender

Preparations

Material needed for testing:

  • 1 complete mattress is needed for assessment against the requirements of SS 876 00 10.
  • 3 complete mattresses are needed in case of a customer complaint dispute.
Anna Bergstrand

Contact person

Anna Bergstrand

Enhetschef

+46 10 516 58 54

Read more about Anna

Contact Anna
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.

* Mandatory By submitting the form, RISE will process your personal data.

Contact

Cannot find what you are looking for or are you curious about how we can help?

Send message
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.

* Mandatory By submitting the form, RISE will process your personal data.